Quantification of fluorescence angiography in a porcine model

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Quantification of fluorescence angiography in a porcine model. / Nerup, Nikolaj; Andersen, Helene Schou; Ambrus, Rikard; Strandby, Rune Broni; Svendsen, Morten Bo Søndergaard; Madsen, Mads Holst; Svendsen, Lars Bo; Achiam, Michael Patrick.

In: Langenbecks Archives of Surgery, Vol. 402, No. 4, 06.2017, p. 655-662.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Nerup, N, Andersen, HS, Ambrus, R, Strandby, RB, Svendsen, MBS, Madsen, MH, Svendsen, LB & Achiam, MP 2017, 'Quantification of fluorescence angiography in a porcine model', Langenbecks Archives of Surgery, vol. 402, no. 4, pp. 655-662. https://doi.org/10.1007/s00423-016-1531-z

APA

Nerup, N., Andersen, H. S., Ambrus, R., Strandby, R. B., Svendsen, M. B. S., Madsen, M. H., Svendsen, L. B., & Achiam, M. P. (2017). Quantification of fluorescence angiography in a porcine model. Langenbecks Archives of Surgery, 402(4), 655-662. https://doi.org/10.1007/s00423-016-1531-z

Vancouver

Nerup N, Andersen HS, Ambrus R, Strandby RB, Svendsen MBS, Madsen MH et al. Quantification of fluorescence angiography in a porcine model. Langenbecks Archives of Surgery. 2017 Jun;402(4):655-662. https://doi.org/10.1007/s00423-016-1531-z

Author

Nerup, Nikolaj ; Andersen, Helene Schou ; Ambrus, Rikard ; Strandby, Rune Broni ; Svendsen, Morten Bo Søndergaard ; Madsen, Mads Holst ; Svendsen, Lars Bo ; Achiam, Michael Patrick. / Quantification of fluorescence angiography in a porcine model. In: Langenbecks Archives of Surgery. 2017 ; Vol. 402, No. 4. pp. 655-662.

Bibtex

@article{ae069d59cdc44fd398fc9bb94ad1de6b,
title = "Quantification of fluorescence angiography in a porcine model",
abstract = "PURPOSE: There is no consensus on how to quantify indocyanine green (ICG) fluorescence angiography. The aim of the present study was to establish and gather validity evidence for a method of quantifying fluorescence angiography, to assess organ perfusion.METHODS: Laparotomy was performed on seven pigs, with two regions of interest (ROIs) marked. ICG and neutron-activated microspheres were administered and the stomach was illuminated in the near-infrared range, parallel to continuous recording of fluorescence signal. Tissue samples from the ROIs were sent for quantification of microspheres to calculate the regional blood flow. A software system was developed to assess the fluorescent recordings quantitatively, and each quantitative parameter was compared with the regional blood flow. The parameter with the strongest correlation was then compared with results from an independently developed algorithm, to evaluate reproducibility.RESULTS: A strong correlation was found between regional blood flow and the slope of the fluorescence curves (ROI I: Pearson r = 0.97, p < 0.001; ROI II: 0.96, p < 0.001) as the normalized slope (ROI I: Pearson r = 0.92, p = 0.004; ROI II: r = 0.96, p = 0.001). There was acceptable correlation of the slope of the curve between two independently developed algorithms (ROI I+II: Pearson r = 0.83, p < 0.001), and good resemblance was found with the Bland-Altman method, with no proportional bias.CONCLUSIONS: Perfusion assessment with quantitative indocyanine green fluorescence angiography is not only feasible but easy to perform with commercially available equipment and readily accessible software.",
author = "Nikolaj Nerup and Andersen, {Helene Schou} and Rikard Ambrus and Strandby, {Rune Broni} and Svendsen, {Morten Bo S{\o}ndergaard} and Madsen, {Mads Holst} and Svendsen, {Lars Bo} and Achiam, {Michael Patrick}",
year = "2017",
month = jun,
doi = "10.1007/s00423-016-1531-z",
language = "English",
volume = "402",
pages = "655--662",
journal = "Langenbecks Archives of Surgery",
issn = "1435-2443",
publisher = "Springer",
number = "4",

}

RIS

TY - JOUR

T1 - Quantification of fluorescence angiography in a porcine model

AU - Nerup, Nikolaj

AU - Andersen, Helene Schou

AU - Ambrus, Rikard

AU - Strandby, Rune Broni

AU - Svendsen, Morten Bo Søndergaard

AU - Madsen, Mads Holst

AU - Svendsen, Lars Bo

AU - Achiam, Michael Patrick

PY - 2017/6

Y1 - 2017/6

N2 - PURPOSE: There is no consensus on how to quantify indocyanine green (ICG) fluorescence angiography. The aim of the present study was to establish and gather validity evidence for a method of quantifying fluorescence angiography, to assess organ perfusion.METHODS: Laparotomy was performed on seven pigs, with two regions of interest (ROIs) marked. ICG and neutron-activated microspheres were administered and the stomach was illuminated in the near-infrared range, parallel to continuous recording of fluorescence signal. Tissue samples from the ROIs were sent for quantification of microspheres to calculate the regional blood flow. A software system was developed to assess the fluorescent recordings quantitatively, and each quantitative parameter was compared with the regional blood flow. The parameter with the strongest correlation was then compared with results from an independently developed algorithm, to evaluate reproducibility.RESULTS: A strong correlation was found between regional blood flow and the slope of the fluorescence curves (ROI I: Pearson r = 0.97, p < 0.001; ROI II: 0.96, p < 0.001) as the normalized slope (ROI I: Pearson r = 0.92, p = 0.004; ROI II: r = 0.96, p = 0.001). There was acceptable correlation of the slope of the curve between two independently developed algorithms (ROI I+II: Pearson r = 0.83, p < 0.001), and good resemblance was found with the Bland-Altman method, with no proportional bias.CONCLUSIONS: Perfusion assessment with quantitative indocyanine green fluorescence angiography is not only feasible but easy to perform with commercially available equipment and readily accessible software.

AB - PURPOSE: There is no consensus on how to quantify indocyanine green (ICG) fluorescence angiography. The aim of the present study was to establish and gather validity evidence for a method of quantifying fluorescence angiography, to assess organ perfusion.METHODS: Laparotomy was performed on seven pigs, with two regions of interest (ROIs) marked. ICG and neutron-activated microspheres were administered and the stomach was illuminated in the near-infrared range, parallel to continuous recording of fluorescence signal. Tissue samples from the ROIs were sent for quantification of microspheres to calculate the regional blood flow. A software system was developed to assess the fluorescent recordings quantitatively, and each quantitative parameter was compared with the regional blood flow. The parameter with the strongest correlation was then compared with results from an independently developed algorithm, to evaluate reproducibility.RESULTS: A strong correlation was found between regional blood flow and the slope of the fluorescence curves (ROI I: Pearson r = 0.97, p < 0.001; ROI II: 0.96, p < 0.001) as the normalized slope (ROI I: Pearson r = 0.92, p = 0.004; ROI II: r = 0.96, p = 0.001). There was acceptable correlation of the slope of the curve between two independently developed algorithms (ROI I+II: Pearson r = 0.83, p < 0.001), and good resemblance was found with the Bland-Altman method, with no proportional bias.CONCLUSIONS: Perfusion assessment with quantitative indocyanine green fluorescence angiography is not only feasible but easy to perform with commercially available equipment and readily accessible software.

U2 - 10.1007/s00423-016-1531-z

DO - 10.1007/s00423-016-1531-z

M3 - Journal article

C2 - 27848028

VL - 402

SP - 655

EP - 662

JO - Langenbecks Archives of Surgery

JF - Langenbecks Archives of Surgery

SN - 1435-2443

IS - 4

ER -

ID: 169017278